You may be surprised to find that some enclosure manufacturers advertising ASSE 1060 compliance don't provide a heat source, especially one that works with enclosure installations that satisfy ASSE's stringent requirements. At Safe-T-Cover, we make this a priority.
ASSE 1060 is the performance standard for enclosures that protect backflow preventers and other above-ground water equipment. It certifies how an enclosure performs in the field, not just how it's built.
In 2006, the American Society of Sanitary Engineering updated the standard. The Class I rating is the highest tier, and it requires the enclosure and its heater to hold a 40°F interior when the outside temperature drops to -30°F. The heat source must also be listed for wet and damp environments, which rules out most heaters sold for this use.
The Importance of ASSE Certification
ASSE accreditation isn't something to take lightly. For over 110 years, ASSE has advocated for consistent practices in plumbing manufacturing and installation, and its certification and rating system is the gold standard in the industry.
Once a product is approved and certified, that's really only the beginning. According to ASSE, the production facility must be reviewed and renewed annually, and an approved product is subject to renewal every five years. That ongoing commitment to product integrity is something we at Safe-T-Cover take seriously, and it's reflected in every facet of our business.
Meeting the Class I Standard
Meeting ASSE's demanding standards for Class I designation has real-world implications beyond the certification itself.
Some years ago, the North Carolina state government needed to retrofit 55 double-check assemblies from underground vaults to above-ground reduced pressure zone backflow preventers in enclosures. They needed more robust freeze protection, so they researched every enclosure manufacturer with heaters that satisfy the ASSE 1060 Class I requirements.
The state chose Safe-T-Cover's backflow enclosures with our patented slab-mounted heaters, providing freeze protection for the equipment that protects the state's water supply.
Not All Options Meet the Mark
Not every option on the market reaches the standards ASSE insists upon for 1060's top classes.
Some products call themselves radiant heat solutions, but no spec sheets or design information are readily available, so they can't be rated for or compared to any standard.
Cable-wrap or tape is the next option. It provides a limited five watts per foot and is only effective for pipes up to two inches in diameter. It remains a popular method for these smaller jobs, and we do sell a Chromalox heater cable for this application.
Finally, there are Class I standard-meeting Safe-T-Cover sealed floor heaters. These wet-damp rated heaters warm internal equipment as well as riser pipes beneath the slab. Their rugged designs have protected backflow preventers in the most severe environments for years.

In side-by-side tests conducted at Tennessee Technological University in 1997, the floor-based heater allowed as much as 32% fewer thermostat on-off cycles on cold-weather days than its wall-mounted counterpart.
What Heaters Do Not Meet ASSE 1060 Class I Requirements?
Most fiberglass enclosure and aluminum shelter manufacturers use wall-mounted heaters. Because there must be room for a door, wall heaters mount to only one side. They must also sit a minimum of 12 inches off the slab because they aren't sealed and aren't suitable for wet or damp conditions.
Since warm air rises, their heat channels through the top of an enclosure long before the interior reaches a uniform temperature. In addition to being noncompliant with the Class I standard, they simply can't deliver the freeze protection a slab mounted heater provides.

Use a Safe-T-Cover ASSE 1060 Class I Enclosure-Heater Combination
If your municipality gets frost or snow, make certain your backflow enclosure meets ASSE 1060 Class I standards and contains a heater that meets them, too. Anywhere temperatures drop below 32°F should be protected this way, so freezing and failure never put the water supply at risk of contamination or interruption.
Meet the standard in every way: follow local building codes and ordinances, protect your property and the water supply, and specify ASSE 1060 Class I enclosures with slab mounted heaters.
Take a look at our heater options or contact us today to discuss your next project.
FAQ
What is ASSE 1060?
ASSE 1060 is the standard that certifies performance for enclosures protecting backflow preventers and similar above-ground equipment. The Class I rating requires an enclosure and its heater to hold a 40°F interior at outside temperatures as low as -30°F.
Why does a slab-mounted heater matter?
A sealed, slab-mounted heater warms equipment and riser pipes from the floor and meets the Class I requirement for wet and damp environments. Wall-mounted heaters don't, which is why they can't deliver the same freeze protection.