List Price: $1,465
Find the best power failure monitoring system and power supply temperature monitor for your industrial enclosures. Get alerted if there's a problem with your equipment due to power failure, temperature and more.
List Price: $1,465
The Sensaphone 1400 Monitoring System monitors up to four inputs. It's able to function even in harsh conditions. The system includes dry contact, 2.8K and 10K thermistor inputs. It also features 4-20mA support, allowing third-party sensor integration, including wireless sensors.
| Communication Method | Phone Line |
| Number of Inputs | 4 |
| Input Types |
Contact, 2.8K, 10K , 4-20mA
|
| Temperature Sensing Range |
-109° to 168°F | -85° to 76°C
|
| Output Relay | One universal input relay Manual or automatic alarm switching |
| Remote Access | Call in to check status and make programming changes Microphone for listen in status |
| Local Access | Keypad and speaker for local programming. Easy voice prompted programming. Password Protected Recent alarm history playback LEDs |
| Alarm Notification | Four custom voice phone calls |
| Power Supply | Plug in power supply also monitors for power failures Internal battery backup |
| Battery Backup Time | 24 hours |
| Physical | 12.1 x 7.3 x 4.5” | 53 x 198 x 223mm • 5lbs | 2.2kg |
| Warranty | 2 years |
| Enclosure | Solid Door Enclosure: ABS/PC Blended Plastic, UL94-5VB Flammability rating, NEMA Type 1, 2, 3, 3R, 4, 4X, 12 & 13, IEC529, IP66 Clear Door Enclosure: ABS/PC blended plastic, UL94–5VB flammability rating; UV stabilized. NEMA Type 1, 2, 3, 3R, 4, 4X, 12 &13, IEC529–IP65 |
| Standards | FCC Part 15 Class A, USA Emission Standards FCC Part 68 (47 C.F.R. Part 68), USA Telecommunications Standards ICES-003 Issue 4 Class A, Canadian Emission Standards Complies with CS-03 Issue 8, Canadian Telecommunications Standards NRTL Listed for compliance to UL60950-1, USA Safety Standards NRTL Listed for compliance to CSA C22.2 No. 60950-1, Canadian Safety Standards |
List Price: $3,018*
*Annual fee not included
The Sentinel Monitoring System with cellular modem offers an easy-to-install, easy-to-configure monitoring solution for locations with no access to a landline or internet connection. The Sentinel monitors up to 12 different environmental and equipment status conditions including temperature, humidity, power failure and water detection. When the system identifies issues, it instantly sends alerts via phone, text or email over a cellular connection.
|
Communication Method |
Choose between 3G or 4G/LTE Cellular Modem for use on Verizon, AT&T or Rogers |
|
Number of Inputs |
12 |
|
Input Types |
Contact, 2.8K, 10K, 4-20mA |
|
Temperature Sensing Range |
-109° to 168°F | -85° to 76°C |
|
Output Relay |
One low voltage NO/NC relay output Manual or automatic alarm switching |
|
Remote Access |
Website to access status and programming |
|
Local Access |
LEDs for Alarm Status, Power Status, and Cellular link |
|
Alarm Notifications |
An unlimited number of email, text or phone calls |
|
Power Supply |
Plug in power supply also monitors for power failures |
|
Data Logging |
Unlimited samples securely stored on the Sentinel servers Programmable sampling Interval - 1 min to 24 hrs |
|
Battery Backup |
8-Hour rechargeable battery backup for both the Sentinel & Cellular modem included |
|
Physical |
12.5 x 12.2 x 7.0” | 318 x 310 x 178mm |
Sensaphone Sentinel Monitoring System User's Manual
Sensaphone Sentinel Monitoring System with Cellular Modem Manual Addendum
Sensaphone Sentinel Monitoring System with Cellular Modem Subscription Agreement
Sensaphone Sentinel Monitoring System with Cellular Modem Popular Sensors and Accessories
Sensaphone Sentinel Monitoring System with Cellular Modem Subscription Pricing
Sensaphone Sentinel Monitoring System with Cellular Modem Technical Specs
List Price: $2,864
The Safe-T-Cover TAPF series alarm systems activate an audible alarm as well as a strobe light in the event of a power failure or whenever the temperature inside the enclosure drops below the set point.
This alarm consists of a painted NEMA-12 rated cabinet, 12VDC battery, AC battery charger, relays, 90 decibel horn, strobe light, thermostat and the temperature sensor. This alarm is designed to activate both the vision strobe light and the audible alarm if either the enclosure loses power or if the internal temperature falls below the owner-managed thermostat set point. Extra contacts are provided to interface with other devices.
This alarm is direct-wired into 120 volt, single phase electrical service. Both alarms run off a 12-volt DC battery. The 120V AC electrical power keeps the 12V DC battery system charged. The electronics are encased in a painted, 14-gauge steel NEMA-12 enclosure for superior weather protection.
The TAPF alarm system must be supplied by the same 120V electrical service that supplies the heaters.
| Painted cabinet | 14 guage steel with a NEMA-12 rating |
| Communication Method |
Audible and strobe light alarm. This alarm also has extra contacts to interface with your control room. Piezo Part #PW12D |
| Audible alarm |
30 mA Warble 95 dB minimum |
| Strobe light |
Ingram Part SK12VDC 30 flashes/minute 90mA Max current draw |
| Remote Access | No remote access |
| Contacts | Dry contacts are rated for 10 ADC @ 24 VDC or 10 AAC @120 VAC. |
| Alarm Locations | Audible and strobe light alarms are attached to the outside of the enclosure. |
| Power Supply | Direct wired to 120 Volt electrical. 240 Volt power can't be used |
| Physical | 9"W x 9"L x 13" H overall |
| Battery Backup | 24-Hour rechargeable 12VDC battery backup is included |
Both are enclosure monitoring systems designed for equipment protection, but they differ in scale and communication. The Sensaphone 1400 monitors up to four inputs over a standard phone line and notifies up to eight people by phone. The Sentinel monitors up to 12 inputs and uses cellular link alarm notifications, sending an unlimited number of alerts via email, text, or voice call, which is a better fit for sites without landline or internet access.
Yes. Battery backup is a core part of each system's freeze protection and power protection design. The Sensaphone 1400 provides 24 hours of battery backup. The Sentinel provides eight hours for both the unit and its cellular modem. The Safe-T-Cover TAPF includes a 24-hour rechargeable 12VDC battery for continued alarm and control during freezing conditions.
The Sensaphone 1400 and Sentinel both support dry contact, 2.8K, 10K thermistor, and 4-20mA, making them compatible with a range of third-party and wireless devices.
The Sensaphone 1400 uses a rugged NEMA-4X rated enclosure (also rated NEMA 1/2/3/3R/4/4X/12/13) built for corrosion resistance and durability in harsh conditions. The Safe-T-Cover TAPF uses a painted 14-gauge steel NEMA-12 enclosure for weather protection against freezing temperatures and general wear.
Installation requires direct wiring into a 120-volt, single-phase electrical service and must be supplied by the same ground and electrical service that powers associated heaters. The incoming AC power keeps the 12VDC battery charged, allowing for uninterrupted performance.
The Sensaphone 1400 delivers custom recorded voice alerts by phone. The Sentinel sends alarm notifications via phone, text, or e-mail over its cellular connection to an unlimited number of users. The Safe-T-Cover TAPF uses a 90+ dB audible horn and strobe light for on-site alerting instead of remote monitoring.
These monitoring and alarm systems are designed to protect equipment enclosures exposed to freezing temperatures, power loss, or environmental threats. This includes heated enclosures for backflow prevention devices like RPZ and DCV as well as pumps, water meters and other equipment housings that need continuous temperature and power monitoring.
An enclosure monitoring system gives you the ability to track temperature, humidity, power status, and alarm status in real-time. Sensors placed inside the backflow enclosure detect freezing temperatures before they cause equipment damage by triggering alarm and control functions to alert users immediately. Proactive monitoring is increasingly treated as an industry standard for equipment that can't tolerate downtime from freezing conditions or power threats.
Please contact us by filling out the form via the button below.
We're in the office 8am-4pm Central Time, Monday through Friday.

© 2026 by Hydrocowl, Inc. All Rights Reserved.